What was found
FLOOR SUPPORT CLIPS AT FS 316 AND FS 342 LT ARE CORRODED. REMOVED CORROSION ON LT FLOOR SUPPORT CLIPS CORROSION DETERMIND TO BE OUT OF LIMITS IAW SRM 51-21-06 DUE TO CORROSION AROUND FASTENER HOLES. REMOVED AFT SUPPORT CLIP & BRACKET IAW SRM 51-42-06 LOCATED, DRILLED, AND INSTALLED NEW CLIP AND BRACKET P/N 601R31527-217 & 601R31527-137 IAW SRM 51-42-06 & 51-40-11 REMOVED FWD SUPPORT CLIP & BRACKET IAW SRM 51-42-06. LOCATED, DRILLED, AND INSTALLED NEW FWD CLIP & BRACKET IAW SRM 51-42-06 & 51-40-11.