What was found
CRACK AT FS 333 FRAME TOOLING HOLE BETWEEN STR 1L AND STR 0. LOCATED AND DRILLED SERVICEABLE FRAME PN 601R32004-41 IAW SRM 51-40-11. INSTALLED NEW FRAME AT FS 333 IAW SRM 51-42-06 AND 51-42-21. PN 601R32004-41.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK AT FS 333 FRAME TOOLING HOLE BETWEEN STR 1L AND STR 0. LOCATED AND DRILLED SERVICEABLE FRAME PN 601R32004-41 IAW SRM 51-40-11. INSTALLED NEW FRAME AT FS 333 IAW SRM 51-42-06 AND 51-42-21. PN 601R32004-41.