What was found
BS 280 FLOORBEAM FWD ANGLE IS CORRODED. LOCATED AND DRILLED A NEW ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED THE REPLACEMENT ANGLE IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 280 FLOORBEAM FWD ANGLE IS CORRODED. LOCATED AND DRILLED A NEW ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED THE REPLACEMENT ANGLE IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01