What was found
PRESSURE FLOOR SUPPORT BEAM INTERCOSTAL CLIPS ARE CRACKED AT FS 484.00 LBL 27 AND LBL 36. C/A: REMOVED & REPLACED CLIP AT LBL 27 IAW SRM 51-42-21. FOR LBL 36 COMPLIED WITH REO 601R-53-41-059 REV B 2009-09-16
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PRESSURE FLOOR SUPPORT BEAM INTERCOSTAL CLIPS ARE CRACKED AT FS 484.00 LBL 27 AND LBL 36. C/A: REMOVED & REPLACED CLIP AT LBL 27 IAW SRM 51-42-21. FOR LBL 36 COMPLIED WITH REO 601R-53-41-059 REV B 2009-09-16