What was found
FS280 RH COCKPIT FLOOR BEAM HAS ON INDICATION 2.1" LONG BY 100% FSH AT THE UPPER SECTION, FAILED NDT INSPECTION. CUT LINE REQUIRES EXTENSION. EXTENDED CUT OUT AND REMOVED ALL BURRS AND SHARP EDGES IAW STEPS 1 AND 2 OF REO 670-53-11-896 REV-- DATE 2015-03-17. NEW CUTLINE REQUIRES NDT. PERFORMED EDDY CURRENT OF FS280 RH FLOOR BEAM CUTLINES IAW REO 670-53-11-896 STEP 3 NO INDICATIONS NOTED AT THIS TIME. REQUIRES REMAINING STEPS OF REO 670-53-11-893. COMPLIED WITH REMAINING STEPS OF REO 670-53-11-896 REV--DATED 2015-03-17. REMOVED AND REPLACED ANGLE CC670-33199-35 IAW REO 670-53-11-896 REV--DATED 2015-03-17.