What was found
CORROSION ON FLOOR PANEL SUPPORT ANGLE AT FS 280. ANGLE CORRODED BEYOND LIMITS IAW CRJ900 SRM FIG 53-00-00-901-803. REMOVED FWD J-ANGLE IAW CRJ900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 AND 51-42-22-001-001-A01. P/N: CC670-34095-3. NEW SERVICEABLE J-ANGLE P/N: CC670-34095-55 REQUIRES LOCATE AND DRILL. D.FIGHT 11/21/19 C/A: 2. LOCATED AND DRILLED NEW J-ANGLE IAW CRJ900 SRM 51-40-11-001-001-A01. NEW J-ANGLE REQUIRES INSTALL. INSTALLED NEW SERVICEABLE J-ANGLE AT FS 280 IAW CRJ900 SRM 51-42-06-001-001-A01.