What was found
5 EA AREAS OF CRACK INDICATIONS NOTED ON FS 621 RPB WEB IN THE HEEL LINE AREA OF VERT POST. 1ST AREA AT RBL 9 WL 127 - 132.5 50% FSH, SECOND AREA AT RBL 9 WL 110 - WL 115 60% FSH, THIRD AREA AT LBL 18 WL 127.25 - WL 135 50% FSH, 4TH LBL 18 WL 100.5 - WL 105 60% FSH AND 5TH AREA AT LBL 36 WL 106 - WL 107 65% FSH. MARKED ON A/C WITH ORANGE TAPE. ALL 5 EA AREAS FAILED NDT. CUT AWAY DAMAGED PORTIONS OF WEB IAW REO 601R-53-61-1240 PART A OPTION 1 STEP 1 REV D DATED 10/31/16. NDT REQUIRED IAW PAT A OPTION 1. HFEC OF REPAIRED AREAS IAW BOMBARDIER REO 601R-53-61-1240 STEP 4 OF PART 1 OPTION 1. INDICATION NOTED AT RBL 9 REPAIR AWL 127-132.5 .700" LONG 75% FSH REMAINING INSPE. NO INDICATIONS NOTED AT THIS TIME. INDICATION NOTED AT THE RBL 9 REPAIR AREA Z MEMBER OB FACE WL 127 - 132.5 .700" LONG VERTICALLY AND 75% FSH. MARKED INDICAITON AREA ON A/C. FAILED NDT. CUT AWAY DAMAGED PORTION OF Z MEMBER AT RBL 9 IAW REO 601R-53-61-1240 PART A OPTION 1 VIEW LL. NDT REQUIRED PER PART A OPTION 1 OF BOMBARDIER REO 601R-53-61-1240 REV D DATED 10/31/16. PERFORMED EDDY CURRENT INSPECTION OF CUTLINE EDGES ON Z MEMBER IAW BOMBARDIER REO 601R-53-61-1240 REV D DATED 10/31/16 SHEET 9 PART A STEP 4. NO INDICATIONS NOTED AT THIS TIME. C/W REMAINING STEPS OF REO 601R-53-61-1240. REF JOB 27880105/5601 FOR REMAINING STEPS OF REO 601R-53-61-1240 REV D DATED 10/31/16.