Service difficulty report · Controller · Cndair CL6002C10

Difficulty date
August 16, 2020
Submitted
August 20, 2020
Operation
Air carrier
Aircraft
N511AE
Make and model
Cndair CL6002C10
Aircraft serial
10107
Aircraft time
41,179 hours, 31,251 cycles
Part
Controller
Part number
GG690950265
Part serial
00485
Condition
Failed
Location
Acs
Part time
12,990 hours, 12,006 cycles
Stage of operation
IN
How discovered
O
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW THE BROUGHT AIRCRAFT INTO FNT LAST NIGHT HAD NO ISSUES. UPON ARRIVING FOR OUTBOUND FLIGHT, FOUND A WRITE-UP FOR A BURNING ELECTRICAL SMELL IN AFT OF AIRCRAFT. CREW ALSO FOUND MULTIPLE BREAKERS POPPED. UPON START-UP CREW ALSO FOUND MULTIPLE LRU INOP, ACSC INOP, AND GPWS INOP. THIS IS ALL CONSISTENT WITH AN ISSUE WITH THE GROUND POWER UNIT SHORTING OUT THE ELECTRICAL SYSTEM. PARTS AND MECHANICS ARE FLYING IN FROM DAY ON THE REPO COMING TO RESCUE THE FLIGHT. UPON ARRIVAL FOUND CBP-1 K6 POPPED ALSO. SWAPPED ACSC 1/2 FAULT CHANGED J4 P2 L1, P1. RETURNED TO ORIGNAL CONFIG SEE NEXT PAGE FOR FURTHER MTX. REF. AMM 21-61-04-000/400-801. REMOVED AND REPLACED EGPWS COMPUTER IAW CRJ 700 AMM 34-42-01-000/400-801-A01