Service difficulty report · Sensor · Cndair CL6002D24

Difficulty date
October 15, 2020
Submitted
October 19, 2020
Operation
Air carrier
Aircraft
N593NN
Make and model
Cndair CL6002D24
Aircraft serial
15405
Aircraft time
10,379 hours, 9,545 cycles
Part
Sensor
Part number
6007300
Part serial
BN146161
Condition
Failed
Location
Brake Temp
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MX AIR RETURN TO BHM, DUE TO BRAKE OVERHEAT WARNING MESSAGE. ON CLIMB OUT OF BHM THE BTMS WAS READING 20 ON THE RT OUTBOARD BRAKE. CREW FOLLOWED THE QRH AND LOWERED THE GEAR BACK DOWN AFTER TAKEOFF. TEMP WAS NOT GOING DOWN AND PER QRH HAD TO RETURN TO NEAREST SUITABLE AIRPORT. PAX WERE NOT TOLD TO BRACE, TRUCKS WERE ROLLED AND FLIGHT DID NOT LAND OVERWEIGHT. THE PLANE LANDED NORMALLY BACK IN BHM. BEFORE EXITING THE RUNWAY CREW STOPPED THE AIRCRAFT AND ASKED THE GROUND CREW TO VISUALLY INSPECT THE TIRE, JUST IN CASE OF A BLOWOUT. GROUND CREW DID NOT SEE ANYTHING AND THE PLANE CONTINUED BACK TO THE GATE. DEFERRED RT OUTBOARD BRAKE TEMP MONITORING READOUT, PER MEL 32-46-01 CAT C OPT 4. M/FUNCTION C/W. REMOVED AND REPLACED THERMOCOUPLE SENSOR ON ROB BRAKE, IAW CRJ900 AMM. PERFORMED SELF TEST OF THERMOCOUPLE SENSOR ALL BRAKES TESTED WITHIN RANGE. THIS CLEARS MEL.