What was found
SMOKE IN CABIN JUST PRIOR TO LANDING, SMELL CAUSED FA TO LOSE CONSCIOUNESS / PERFORMED GVI AND GENERAL CLEANING OF APU INLET SCREEN IAW CRJ 700 SRM 51-26-00-001-001 TO REMOVE CICADAS FROM APU INLET SCREEN, PERFORMED OPS CHECK OF AIR CONDITIONING DISTRIBUTION SYSTEM AND RAN BOTH PACKS FOR EXTENDED PERIOD OF TIME IAW CRJ 700 AMM 21-51-00-710-801, PERFORMED ENGINE AND ECS DRY OUT PROCEDURE IAW CRJ 700 AMM 72-00-00-100-803-A01-PSA, PEFORMED OPS CHECK OF GALLEY HEATER IAW CRJ 700 AMM 21-23-64-710-801, ALL OPS CHECKS GOOD, NO SMOKE NOTED AT ANY TIME, SMELL OF CICADAS DISSIPATED.PERFORMED OPERATIONAL CHECK OF AIR CONDITIONING DISTRIBUTION SYSTEM AND CYCLE BOTH PACKS IAW CRJ 700 21-51-00-710-801 OPS CHECK GOOD NO FURTHER SMELL NOTED AT THIS TIME AND CHECKED CABIN AFTER REPOSITIONING FROM HARD STAND TO HANGAR NO FURTHER SMELL NOTED AT THIS TIME