What was found
PAX DOOR SILL UPPER AND LOWER FLOOR SUPPORT ANGLES ARE CORRODED. LOCATED, DRILLED AND INSTALLED NEW MID CAP ANGLE P/N: SH670-31825-95 IAW CRJ900 SRM 51-40-11-001-001-A01 AND 51-41-02-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX DOOR SILL UPPER AND LOWER FLOOR SUPPORT ANGLES ARE CORRODED. LOCATED, DRILLED AND INSTALLED NEW MID CAP ANGLE P/N: SH670-31825-95 IAW CRJ900 SRM 51-40-11-001-001-A01 AND 51-41-02-001-001-A01.