Service difficulty report · Sensor · Cndair CL6002D24

Difficulty date
February 7, 2022
Submitted
February 8, 2022
Operation
Air carrier
Aircraft
N567NN
Make and model
Cndair CL6002D24
Aircraft serial
15354
Aircraft time
16,308 hours, 14,598 cycles
System (JASC)
3242 · Brake
Part
Sensor
Part number
6007300
Part serial
BN233201
Condition
Fault Message
Location
700
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
A, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A/C RETURNED TO FIELD DUE TO A PERSISTENT LH BRAKE OVERHEAT MESSAGE. A/C DID LAND OVERWEIGHT, AND RTG UNDER OWN POWER UPON LANDING. BRAKE OVERHEAT MSG AFTER TAKEOFF WITH LH OB BRAKE INDICATING 15. BRAKE APPEARED COOL AFTER LANDING. / DEFERRED LH OB BRAKE TEMP READOUT PER MEL 32-46-01 CAT C OPTION 4. M FUNCTION C/W BY DEACTIVATING AND AND STOWING CONNECTOR PER MEL INSTRUCTIONS. REMOVED AND REPLACED LH OB BRAKE TEMP SENSOR IAW CRJ900 AMM 32-46-01-000/400-801-A01. THIS CLEARS MEL.