What was found
RH UPPER IB TRANSCOWL NYLON TRACK IS BROKEN. PERFORMED EA21-C7-78-710 AS TEMPORARY CORRECTIVE ACTION WITH EDDY CURRENT INSPECTION OF RH UPPER HINGE BEAM TRACK INSERT FASTENER HOLES IN ACCORDANCE WITH NDTM 51-20-006. NO CRACKS FOUND. PERFORMED REO 670-78-30-921 ON THE RH UPPER HINGE BEAM TRACK FASTENER HOLES IAW REO INSTRUCTIONS. THIS TERMINATES EA21-C7-78-710. NO FURTHER ACTION REQUIRED.