What was found
SUPPLEMENTAL RECORD CORRECTION: INSTALLED FWD AND AFT SPIGOT ASSEMBLIES AND SERRATED PLATES IAW CRJ 900 AMM 53-21-23-400-803-A03. ADJUSTED SERRATED PLATES BY ADDING SHIMS TO BOTH PLATES. INSTALLED FWD AND AFT SPIGOT BEARING ASSEMBLIES IAW CRJ 900 AMM 53-21-23-400-803. FWD AND AFT BEARING NOW SPINS FREELY WHEN DOOR IS FULLY LATCHED. PERFORMED FUNCTIONAL TEST OF THE PASSENGER DOOR AND ADJUSTED PULL-IN LEVER STOP IAW CRJ 900 AMM 52-11-00-720-802-A01. ALL CHECKS GOOD.