What was found
SEVERAL NICKS ON LOWER SKIN OF LH INBOARD FLAP FLS 15.00 TO FLS 65.5. SEVERAL NICKS ON LOWER SKIN OF LH INBOARD FLAP FLS 15.00 TO FLS 65.5 WERE BLEND OUT PER CRJ900 SRM 51-12-00-001-001-A01 AND BTW FLS15.00 AND FLS42.00 WAS EVALUATED OUT OF LIMITS PER CRJ900 SRM 57-52-01-101-001-A01 AND WAS REPAIRED PER CRJ900 SRM 57-52-01-201-005-A01 AND BTW FLS42.00 AND FLS65.50 WAS EVALUATED WITHIN LIMITS PER CRJ900 SRM 57-52-01-101-001-A01.