What was found
CORROSION ON MID CAP, LOCATED BTW FS=310 / FS=349 AND LBL 40" AT FUSELAGE FLOOR STRUCTURE. NEW MID CAP, LOCATED BTW FS=310 / FS=349 AND LBL 40" AT FUSELAGE FLOOR STRUCTURE WAS REPLACED PER CRJ-900 SRM 51-41-02-001-001-A01
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON MID CAP, LOCATED BTW FS=310 / FS=349 AND LBL 40" AT FUSELAGE FLOOR STRUCTURE. NEW MID CAP, LOCATED BTW FS=310 / FS=349 AND LBL 40" AT FUSELAGE FLOOR STRUCTURE WAS REPLACED PER CRJ-900 SRM 51-41-02-001-001-A01