As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
F.S. 333 FRAME IS CORRODED BETWEEN STGR 26L TO STGR 26R. REMOVED F.S 333 FRAME SECTOR BETWEEN STGR25R AND 25L IAW STEPS 1 AND 3 OF CRJ900 SRM 53-00-06-201-006-A01. COMPLIED WITH CRJ 900 SRM 53-00-06-201-006-A01 STEPS 4 J 6-7 FABRICATED, LOCATED AND DRILLED NEW FRAME SECTOR PN# SH670-31356-5 BETWEEN STR25L AND STR25R, SPLICE ANGLE 2 EA. FROM MATERIAL S1710-4 & STR25L & STR26R CLIP FROM MATERIAL S6144-13.