As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PERM REPAIR BEFORE 20,720.22 FH - LIGHTNING STRIKE STR24R-STR25R AT FS 235.00 THE SUBJECT CONDITION IS STRUCTURALLY ACCEPTABLE FOR 900 FLIGHT HOURS FROM THE TIME OF INCORPORATION OF THIS REO AT REV IN REF TRFKE00BD723:690-53-11-1621. PERM REPAIR BEFORE 20,720.22 FH - LIGHTNING STRIKE STR24R-STR25R AT FS 235.00 WAS REPAIRED PER REO 690-53-11-1668 REV.--