What was found
IN REF. TRFKE00C9EWX:EA A1-690-55-00012. 526.07FH PERM REPAIR- RH ELEVATOR UPPER SKIN TRAILING EDGE LIGHTNING STRIKE DAMAGE 1. WITHIN 526.07 FH'S. (BEFORE 19,075.19 FH) FROM SECTION I REPAIR OR REPLACE THE DISCREPANT ITEM IN ACCORDANCE WITH APPROVED PROCEDURES.RH ELEVATOR UPPER SKIN TRAILING EDGE LIGHTNING STRIKE DAMAGE 1, IN REF. TO JOB TRFKE00C9EWX WAS REPAIRED PER CRJ-900 SRM 55-21-01-201-001-A01, PER EA NO: A1-690-55-00012A REV.A. SECTION 111- PERMANENT REPAIR AND DO SPECIAL DETAILED INSPECTION CL-690 THRESHOLD 40000 FLIGHT CYCLES, REPEAT 40000 FLIGHT CYCLES PER CRJ-900 SRM 55-21-01-201-001-A01.