What was found
LWR FRAME @F.S 1015 REQUIRES BEING SPLICED FROM STR 25R AND STR 26L FOR ACCESS TO STRINGER REPLACEMENT AT STR 26R. COMPLIED WITH LWR FRAME @F.S 1015 REQUIRES BEING SPLICED FROM STR 25R AND STR 26L IAW MHIRJ REO 670-53-61-2368 REV --.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LWR FRAME @F.S 1015 REQUIRES BEING SPLICED FROM STR 25R AND STR 26L FOR ACCESS TO STRINGER REPLACEMENT AT STR 26R. COMPLIED WITH LWR FRAME @F.S 1015 REQUIRES BEING SPLICED FROM STR 25R AND STR 26L IAW MHIRJ REO 670-53-61-2368 REV --.