What was found
HN00208950 SN: 00795 DISCREPANCY:UPON INSTALLATION OF WINDOW POST, SIDE POST LOWER, AFT FITTING PN: GC212-0045-3 FOUND TO BE GOUGED IN MULTIPLE LAVATIONS AND REQUIRES REPLACEMENT DUE TO NO ALLOWABLE LIMITS IN THIS AREA. CORRECTIVE ACTION: LOCATED, DRILLED, AND DEBURRED SIDE POST LOWER, AFT FITTING PN: GC212-0045-3 IAW CRJ700 SRM 51-40-11-001-001-A01 INSTALLED SIDE POST LOWER, AFT FITTING PN: GC212-0045-3 IAW CRJ700 SRM 51-42-21-001-0014-A01