What was found
CLIP/KLEAT (ANGLE) @ FS310.00 STGR 20, FOUND TO BE CHAFED, CORRODED, REQUIRES R&R CORRECTIVE ACTION: DRILLED, LOCATED, AND INSTALLED NEW SERVICEABLE P/N(SH670-32046-3) CLIP/KLEAT(ANGLE) @ FS310.00 STGR 20 IAW CRJ700 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-23-00-001-001-A01, 51-25-06-001-001-A01, 51-25-16-001-001-A01