What was found
CORROSION ON SETTLEMENT AREA OF FAIRINGS 195AL, 195BB, 195DL, 196AR AND 196DR BTW FS 847.00 TO FS 977.00 AT AFT FUSELAGE WAS REMOVED PER CRJ700 SRM 51-21-06-001-001-A01. ON SKIN SETTLEMENT AREA WAS EVALUATED WITHIN LIMITS PER CRJ-700 SRM 53-51-01-101-003-A01, CRJ700 SRM 53-51-01-101-004-A01 AND CRJ700 SRM 53-51-01-101-002-A01. ON SUPPORT STRUCTURE ANGLE LH (FS879), ANGLE RH (FS879), STRAP LH (FS909), STRAP RH (FS909) AND ANGLE M (FS 939) WERE EVALUATED WITHIN LIMITS PER CRJ700 SRM 53-00-00-101-001-A01, ANGLE LH (FS 939), ANGLE RH (FS 939) AND STRAP MID (FS909) WERE EVALUATED OUT OF LIMITS PER CRJ700 SRM 53-00-00-101-001-A01 AND WERE REPLACED PER CRJ700 SRM 51-42-06-001-001-A01 AND CRJ700 SRM 51-42-13-001-001-A01