What was found
CORROSION ON STGR 19LH AND CONECTOR SUPPORT BTW FS 319 TO FS333 AT MAIN AVIONICS COMPARTMENT. STGR 19L BTW FS 319 TO FS333 WAS EVALUATED OUT OF LIMITS PER CRJ700 SRM 53-00-00-101-001-A01 AND REPLACED PER SRM 51-42-06-001-001-A01 AND CRJ700 SRM 51-42-21-001-001-A01. CORROSION ON CONECTOR SUPPORT BTW FS 319 TO FS333 WAS REMOVED PER SRM 51-21-06-001-001-A01 AND EVALUATED WITHIN LIMITS PER SRM 53-00-00-101-001-A01.