What was found
FORWARD EQUIPMENT COMPARTMENT FLOOR IS CRACKED NEXT TO ADG PUMP. CORRECTIVE ACTION: UPON FURTHER INVESTIGATION FOUND TO BE PREVIOUSLY INSTALLED REPAIR DOUBLER, REFERENCE " REO 670-53-11-509 REV -E DATED 2018-02-08 " REMOVED DAMAGED DOUBLER AND ANGLE IAW CRJ700 SRM 51-42-06-001-001-A01. FABRICATED REPLACEMENT ADG PUMP DOUBLER IAW CRJ700 SRM 51-40-11-001-001-A01 AND SRM 51-24-36-001-001-A01. REFERENCING REO 670-53-11-509 REV -E DATED 2018-02-08 FOR MATERIAL SPECIFICATIONS AND INSTALLED NEW FABRICATED DOUBLER IAW CRJ700 SRM 51-42-06-001-001-A01. REFERENCING REO 670-53-11-509 REV -E DATED 2018-02-08 FOR FASTENER CALLOUT. CC670-33045