Service difficulty report · Transducer · Cndair CL6002C10

Difficulty date
December 24, 2025
Submitted
December 26, 2025
Operation
Air carrier
Aircraft
N546FF
Make and model
Cndair CL6002C10
Aircraft serial
10326
Aircraft time
32,410 hours, 26,230 cycles
Part
Transducer
Condition
Leaking
Location
Zone 100
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HYD SYSTEM 2 LOW PRESSURE CAUTION MSG. IN FLIGHT. EMER DECLARED. / UPON ARRIVAL TO AIRCRAFT CLEANED AFFECTED AREA AND FOUND LEAK COMING FROM THE SYSTEM #2 PRESSURE TRANSDUCER. FOUND THE PRESSURE TRANSDUCER TO BE LOOSE AND HAD A CRUSHED O-RING. REPLACED O-RING AND RETORQUED THE #2 PRESSURE TRANSDUCER IAW CRJ700 AMM 29-31-01-000/400-801. LEAK CHECK AND OPS CHECKS GOOD AT THIS TIME.