What was found
CORROSION ON ATTACHMENT ANGLE OF ACCESS PANEL 542AZ / 642AZ ON MLG SHOCK STRUT BAY. ANGLE OF ACCESS PANEL,642AZ ON MLG SHOCK STRUT BAY WAS CLEANED PER SRM 51-26-00-001-001-A01 AND EVALUATED,DETAILED VISUAL INSPECTION WAS PERFOMED PER 51-11-00-001-001-A01 AND NO CORROSION AND DAMAGES WERE FOUND AND CORROSION ON ATTACHMENT ANGLE OF ACCESS PANEL 542AZ ON MLG SHOCK STRUT BAY WAS REMOVED PER SRM 51-21-06-001-001-A01 , EVALUATED,THEREFORE IS OUT OF LIMITS PER SRM 53-00-00-101-001-A01 AND REPLACED PER SRM 51-42-21-001-001-A01.