What was found
FLOOR SILL MID CAP ANGLE IS CORRODED AROUND FASTENER HOLES BETWEEN FS310 AND FS349. LOCATED, DRILLED AND INSTALLED NEW SERVICABLE PART [P/N SH670-31825-3] IAW CRJ 700 SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SILL MID CAP ANGLE IS CORRODED AROUND FASTENER HOLES BETWEEN FS310 AND FS349. LOCATED, DRILLED AND INSTALLED NEW SERVICABLE PART [P/N SH670-31825-3] IAW CRJ 700 SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.