What was found
BS 349 FRAME IS CORRODED BETWEEN STGR 26L TO STGR 26R. REMOVED DAMAGED FS 349 LOWER FRAME SEGMENT IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-21-001-001-A01. LOCATED AND DRILLED NEW SERVICEABLE FS 349 FRAME LOWER SEGMENT IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-21-001-001-A01. LOCATED AND DRILLED LOWER ATTACHING FLANGE ON NEW SERVICEABLE FS 349 FRAME IAW SRM 51-42-06-001-001-A01. FABRICATED NEW SERVICEABLE FACTORY SPLICE REWORK ANGLE REFERENCE DWG SH670-32002 FOR MATERIAL CALL OUT AND SPECIFICATIONS INSTALLED NEW SERVICEABLE FS 349 FRAME LOWER SEGMENT IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-21-001-001-A01.