What was found
DURING TAKEOFF ROLL, A BLEED WARNING MESSAGE ILLUMINATED. THE CREW ABORTED TAKEOFF AND RETURNED TO THE GATE WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE LEFT HIGH PRESSURE BLEED SHUTOFF VALVE IN ACCORDANCE WITH DORNIER MANTENANCE MANUAL 36-11-07. FUNCTION CHECKS WERE GOOD AND THE AIRCRAFT WAS RETURNED TO SERVICE.