As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THE PREFLIGHT INSPECTION, AN EMERGENCY LIGHT WAS NOTED TO BE INOPERATIVE. MAINTENANCE INSPECTED AND REPLACED THE 5LK BATTERY PACK IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-51-01. OPERATION CHECKS WERE COMPLETED, AND THE AIRCRAFT WAS RETURNED TO SERVICE.