What was found
DURING THE PREFLIGHT INSPECTION, THE EMERGENCY FLOOR LIGHTING AT ROWS FOUR, FIVE AND SIX, WERE FOUND TO BE INOPERATIVE. OUTSTATION MAINTENANCE INSPECTED AND APPROVED THE AIRCRAFT FOR A FERRY FLIGHT TO PIT, TO FACILITATE REPAIR. THE FERRY FLIGHT TOOK PLACE WITHOUT ANY INCIDENT. PIT MAINTENANCE INSPECTED AND REPLACED THE 5LK EMERGENCY BATTERY PACK IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-51-01. OPERATIONAL CHECKS WERE COMPLETED, AND THE AIRCRAFT WAS RETURNED TO SERVICE.