What was found
FLT DIVERTED DUE TO ODOR IN CABIN AROUND SEAT ROWS 4 TO 7. AT ABOUT 10,000 FT & CLIMBING ODOR FIRST NOTICED BY FLT TEAM MEMBER & THEN DISAPPEARED. LATER, AT ABOUT 30,000 FT ODOR RETURNED. REPORTED IT TO BE LIKE ELECTRIC OR PLASTIC ODOR & THAT IT WAS STRONG. CAPTAIN TO DIVERTED FOR INVESTIGATION. ODOR AGAIN DISAPPEARED BEFORE ARRIVAL. ACCOMPLISHED VISUAL INSPECTION OF E&E BAY, FWD CARGO BIN, CABIN CEILING PANELS AND PSU`S IN AFFECTED AREA. NO FINDINGS REF AMM 25-23-41-04, TSM 24-00-00-810-823. ACCOMPLISHED CABIN TEMP CONT SYS TEST. OPS OK IAW 21-63-00-710-004. PLACED IFE SYS INOP AS PRECAUTION. ACFT RETURNED TO SERVICE & WITH NO FURTHER OCCURRENCE. FURTHER INSP & CHECKS CARRIED OUT, NO DEFECTS FOUND. IFE CB`S RESTORED & SYSTEM PWR TURNED ON. OPERATED SYS FOR 5 HRS. ALL OPS CHECK NORMAL IAW MM 44-27-01. THE IFE WAS RETURNED TO SERVICE & IS OPERATING NORMALLY. (K)