What was found
REPORT THAT THE GUST LOCK ON R1 DOOR NOT LOCKING. NYLON BUSHINGS WERE WORN, REPLACED THE BUSHINGS IAW AMM 52-11-12-00-802. ACFT RETURNED TO SERVICE.