As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
REPORTED THE FOLLOWING FAULT. AIR PACK 1 REGUL FAULT. R&R NR 1 COMPRESSOR OUTLET TEMP SENSOR 12HH IAW AMM 21-61-11-000-001-A. ACCORDING TO THE OPERATOR`S RECORDS, ALL AIRWORTHINESS DIRECTIVES, SERVICE BULLETINS, STC`S AND PMA`S ARE IN FULL COMPLIANCE WITH THE TYPE DESIGN CERTIFICATE AND ASSOCIATED REGULATORY REQUIREMENTS.