What was found
THE EMERGENCY LIGHTS CYCLED ON AND OFF UNCOMMANDED. UPON TROUBLESHOOTING, TECHNICIANS ALSO DISCOVERED EMERGENCY LIGHTS ABOVE L1 DOOR & R1 DOOR, ROW 1, 3, & 4 INOPERATIVE. R & R EPSU BATTERY AT 10WL. OPS CHECKED GOOD IAW AMM 33-15-138 PB401. NO FURTHER REPORTED FAULTS ON SUBSEQUENT FLIGHTS.