SDR VTZA97324

Service difficulty report · Switch · Jetair JETSTM4101

Difficulty date
June 13, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N328UE
Make and model
Jetair JETSTM4101
Aircraft serial
41083
Part
Switch
Condition
Dirty
Location
Baggage Door
Stage of operation
TO
Nature of condition
N
Precautionary procedure
C, D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

IAD/EWR - FLT 6295 - DURING TAKEOFF AT 1600 HOURS ON 6-13-97, ABORTED TAKEOFF DUE TO BAGGAGE DOOR WARNING LIGHT ILLUMINATED ON TAKEOFF ROLL. AIRCRAFT RETURNED TO GATE WITH NO FURTHER PROBLEMS. MAINTENANCE INSPECTED AND OPENED DMI 46221, MEL 52-3. MAINTENANCE CLOSED DMI 46221 ON 6-16-97 BY CLEANING AND LUBING BAGGAGE DOOR MICROSWITCH. AIRCRAFT RELEASED AND APPROVED FOR RETURN TO SERVICE. (X)