SDR VTZA97357

Service difficulty report · Valve · Jetair JETSTM4101

Difficulty date
July 1, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N309UE
Make and model
Jetair JETSTM4101
Aircraft serial
41022
Part
Valve
Part number
14121007431
Condition
Failed
Location
Rt Pack
Stage of operation
TX
Nature of condition
M, J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

IAD/DTW - FLT 6426 - DURING TAXI-OUT AT 0745 HOURS ON 7-1-97, EXPERIENCED A RT DUCT OVERTEMP LIGHT ILLUMINATION. AIRCRAFT RETURNED TO THE GATE WHERE THE MAINTENANCE TECHNICIANS TROUBLESHOT THE DISCREPANCY AND FOUND THE RT PACK OVERTEMP WOULD NOT RESET. MAINTENANCE OPENED A DEFERRED MAINTENANCE ITEM NR 57360 IAW WITH ALL MAINTENANCE PROCEDURES. MAINTENANCE CLOSED DMI 57360 ON 7-2-97 BY REMOVING AND REPLACING TEMP CONTROL VALVE, OPS CHECK OK. AIRCRAFT RELEASED AND APPROVED FOR RETURN TO SERVICE. (X)