As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UNIT BEGINS TRANSMITTING INSTEAD GOING ON STANDBY WHEN ARMING PIN IS PULLED. UNIT IS DESIGNED TO TRANSMIT AFTER WATER ACTIVATION SENSORS ARE MOISTENED. UNIT MALFUNCTIONS BY TRANSMITTING FROM STANDBY WITHOUT MOISTURE BEING APPLIED. THIS UNIT WAS RECEIVED NEW FROM THE DISTRIBUTOR. (X)