Service difficulty report · None · Bombdr BD1001A10

Difficulty date
November 17, 2021
Submitted
November 23, 2021
Operation
Air carrier
Aircraft
N70CR
Make and model
Bombdr BD1001A10
Aircraft serial
20048
Aircraft time
6,439 hours, 3,925 cycles
Part
None
Condition
None
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
E, A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SUPPLEMENTAL REPORT: MAINTENANCE PERFORMED @ KFLL BY APPROVED VENDOR BOMBARDIER SERVICE CENTER CRS LN4R342M. TROUBLE SHOT THE " LH BLEED LEAK" AND "LH PYLON LEAK " MESSAGES. PERFORMED INSPECTION OF LH DETECTOR LOOP WITH NO FAULTS. CHECKED LH MPV AND LH INTERMEDIATE VALVE CLAMPS AND FOUND TORQUE TO BE LOW, RE-TORQUED CLAMPS. PERFORMED HP SYSTEM LEAK TEST FOUND LH INBOARD INTERMEDIATE VALVE V-BAND CLAMP LEAKING. REMOVED AND REPLACED WITH A NEW V-BAND CLAMP. PERFORMED SATISFACTORY OPERATIONAL AND LEAK CHECK OF HP BLEED AIR SYSTEM WITH NO DEFECTS NOTED. ALL WORK ACCOMPLISHED AS PER BOMBARDIER BD 100 AMM 36-11-05. AIRCRAFT RETURNED TO SERVICE WITH NO FURTHER ISSUES