What was found
EMERGENCY EXIT LIGHTS INOP ROW 7 TO 15. FOUND SEVERAL WIRES PULLED AT LIGHT CONNECTIONS THROUGH OUT AIRCRAFT. RECONNECTED LIGHT ASSEMBLY, OPS CHECK OK. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT LIGHTS INOP ROW 7 TO 15. FOUND SEVERAL WIRES PULLED AT LIGHT CONNECTIONS THROUGH OUT AIRCRAFT. RECONNECTED LIGHT ASSEMBLY, OPS CHECK OK. (M)