What was found
DURING C-CHECK, FLOOR TO SIDE WALL SUPPORT WEB CRACKED AROUND NUT PLATE AT BS 847, RBL 18, WL 160. REMOVED DAMAGED PART FABRICATED AND INSTALLED IAW SRM. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FLOOR TO SIDE WALL SUPPORT WEB CRACKED AROUND NUT PLATE AT BS 847, RBL 18, WL 160. REMOVED DAMAGED PART FABRICATED AND INSTALLED IAW SRM. (M)