What was found
FOUND CORROSION UNDER NUTPLATES ON INTERCOSTAL UNDER FLOOR TO SIDEWALL SUPPORT. REMOVED INTERCOSTAL, FABRICATED LEFT INTERCOSTAL, BS 927-947, LBL 22.5, WL 173. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION UNDER NUTPLATES ON INTERCOSTAL UNDER FLOOR TO SIDEWALL SUPPORT. REMOVED INTERCOSTAL, FABRICATED LEFT INTERCOSTAL, BS 927-947, LBL 22.5, WL 173. (M)