What was found
CORROSION IN SEVERAL AREAS HAT CHANNEL AT BS 992, RBL 14 - RBL 20, WL. REMOVED TOTAL OF 20 SQ INCHES, ORIGINAL DEPTH .070. REMOVED CORROSION ON HAT CHANNEL AND SUPPORT ANGLE, HAT SECTION ORIGINAL .070 INCH, REMOVED .004 - .017 FOUND OUT OF LIMITS, SUPPORT ANGLE ORIGINAL .090 INCH, REMOVED .004 INCH - .045 INCH OUT OF LIMITS PER SRM 53-505, APPROX 20 SQ INCHES CLEARED. FABRICATED HAT CHANNEL 7075.T6 .070 THICKNESS STOCK IAW SRM 51-40-05 AND 51-20-1. PRIMED AND PAINTED APPLIED IAW 20-40-02. (M)