What was found
FOUND CORROSION ON FLOOR SUPPORT BS 331, RBL 11, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS REPLACED PER SRM 53-10-51. INSTALLED NEW PART. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON FLOOR SUPPORT BS 331, RBL 11, WL 208. REMOVED CORROSION FOUND TO BE OUT OF LIMITS REPLACED PER SRM 53-10-51. INSTALLED NEW PART. (M)