Service difficulty report · Sleeve · Emb EMB135BJ

Difficulty date
June 8, 2015
Submitted
June 8, 2015
Operation
General aviation
Make and model
Emb EMB135BJ
Part
Sleeve
Part number
M21F10012
Condition
Failed
Location
Bleed Air
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER RE-INSTALLING THE LT AND RT HEAT EXCHANGERS THAT WERE REMOVED FOR CLEANING THE COUPLINGS WERE INSTALLED TO CONNECT THE DUCTWORK BETWEEN THE HEAT EXCHANGER AND THE ACFT. DURING THE LEAK CHECK OF THE HEAT EXCHANGERS WITH BLEED AIR APPLIED IT WAS FOUND THAT 3 OUT OF 4 OF THE COUPLINGS WERE INFLATED BY THE BLEED AIR. THE COUPLINGS IN QUESTION ARE PN M21F1001-2 AND IS INTERCHANGEABLE WITH 815113-7, DATED 4Q09. THE COUPLINGS WERE MANUFACTURED AND THEY HAVE THE FAA PMA STAMP ON THEM. FAILURE OF THESE COUPLINGS IN FLIGHT COULD BE A SERIOUS PROBLEM AS THE ACFT WOULD LOSE ITS SOURCE OF AIR FOR PRESSURIZATION AND AIR CONDITIONING. AT THIS POINT IN TIME I WOULD SUGGEST THAT THESE COUPLINGS ONLY BE SOURCED FROM ACFT MFG PARTS.