As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RCH764/14 KGTB/KGTB DURING CLIMB (HYD 3 ELEV OFF) LEVEL 1 ILLUMINATED. HYD 3 WENT TO 3.8GAL. CONFERED WITH MX AND ACCOMPLISHED AIR RETURN TO KGTB. AFTER GEAR DOWN HYD 3 QUANTITY WENT TO 2.1 AND THE (HYD 3 QTY LOW) LEVEL 1 ALERT ILLUMINATED. FOUND HYD SYSTEM SHUTOFF VALVE SEALS BLOWN. REMOVED AND REPLACED VALVE IAW MM 29-12-95. OPS AND LEAK CHECK GOOD AFTER SYSTEM SERVICED AS REQUIRED. AIRCRAFT OK FOR SERVICE.