What was found
DURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 9. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATED REPAIR BUSHING PER SECTION 12, REINSTALLED BARREL NUT WITH WITH NEW PLI WASHER PER SECTION 10.