What was found
DURING C-CHECK INSPECTION CORROSION FOUND AFT FUSELAGE FLOOR SUPPORT AT STA Y=2007 X=-23.5. REPLACED DAMAGED SUPPORT PER MD11 SRM VOL II 51-31-01 REV 40. REF EGAT NRC U05025.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK INSPECTION CORROSION FOUND AFT FUSELAGE FLOOR SUPPORT AT STA Y=2007 X=-23.5. REPLACED DAMAGED SUPPORT PER MD11 SRM VOL II 51-31-01 REV 40. REF EGAT NRC U05025.