What was found
DURING C CHECK INSPECTION CRACK-FOUND RT WING LE INBD SLAT NR 1 AFT SIDE HAD CRACK 11.5 INCHES LONG AT XIS 247. REMOVED THE RT INBD NR 1 SLAT ASSY COMPLETED PER AMM 27-80-20-000-801 REV 62. REPAIRED THE DAMAGED AREA IAW MD-11 SRM VOL ONE 57-10-00 REV. 40. INSTALLED THE RT INBD NR1 SLAT ASSY IAW 27-80-20-400-801 REV.62. FUNCTIONAL TEST OF THE RT INBD NR1 SLAT RANGE OF MOVEMENT CONDITION CHECK SATIS IAW AMM 27-80-00-710-802 REV. 62. (A) (S)